It
is very important to be as precise as possible when
specifying tank fittings and accessories. Location,
type and size of fittings must be noted clearly on your
drawing. If more then one fitting is being specified,
mark each fitting with a letter A, B, C, etc. Dimensional
drawings are available for all tanks. Print blanks,
draw fittings and fax with your order number to 1-631-563-2546
| Vertical
Bulk Storage Tanks |
|
Plan
View
Calibration strip is at 0
degrees, in line with manway. Specify
in degrees from 0 the location of fittings. |
Elevation
View
Indicate in inches the
height from the center of the fitting to the floor.
|
|
|
|
Example:
Fitting A is at 90°, 48 up
from bottom; Fitting B is at 180°,
30 up from bottom; Fitting C is
at
270°, 20 up from bottom.
NOTE: Use a dotted circle to indicate fittings
which are on the opposite side of the elevation
drawing (see fitting B)
Most Tank Depot vertical bulk storage tanks have
8 x 8 flat sections at least every 90°degrees
along the circumference at the bottom of the side.
These flats are ideal locations for bulk head type
fittings. |
|
End
View
Round Horizontal |
End
View
Leg Horizontal |
Side
View
|
|
|
|
|
|
Drain
Fittings are generally located in one of the ends
of the tank, close to the bottom. Indicate in
inches any fitting(s) that are required in the
top of the tank.
|
| Cylindrical
Open Top Tanks |
|
Plan
View
If more than one fitting is
being specified, indicate in degrees the
location of the fittings. |
Elevation
View
Indicate in inches the height from center of the
fitting to the floor.
|
|
|
|
Example:
Fitting A is at 180°, 15 up
from bottom; fitting B is at 270°,
30 up from bottom.
NOTE 1: Use a dotted circle to indicate fittings
which are on opposite side of the
elevation drawing (see fitting A)
NOTE 2: Never include tank flange in your measurements. |
|
| Indicate
width, length and height of tank using inches. |
Plan
View Indicate in inches the
distance from edge of tank. |
Elevation
View Indicate in inches the
height from the center of the fitting to the
floor.
|
|
|
|
Example:
24 x 36 x 36 HT. Fitting is 18
in from side along the 36 wall, 18 up
from floor.
NOTE:
NEVER INCLUDE TANK FLANGE IN YOUR MEASUREMENTS. |
| Cylindrical
Cone Bottom Tanks |
|
Plan
View If more than one fitting is
being specified, indicate in degrees
the location of the fittings. |
Elevation
View Indicate in inches the height
from the bottom of the straight side to the center
of the fitting. Do not include the cone. Stands
have a lip 1-6
high. Consult sales office for minimum height
of side fittings.
|
|
|
|
Example:
Fitting A is at 0°, 15 up
the straight side; fitting B is at 90°,
20
up from straight side; C is in cone
flat. |
|